R134a Pressure Gauge Chart

Ambient Temperature (°F) Low Side High Side
90° 50-55 psi 250-275 psi
85° 50-55 psi 220-250 psi
80° 45-50 psi 175-220 psi
75° 40-45 psi 150-175 psi

What PSI should a refrigerator compressor be?

A 100 – 300 watt fridge compressor can deliver 0.7 – 1 CFM of air and can reach pressures over 500 psi.

Is r123 a low pressure refrigerant?

For environmental reasons, R-123 is now the low pressure centrifugal refrigerant of choice.

How cold can R134a get?

That fact explains why compressor manufacturers limit the condensing temperature for R407C to around 145–150°F (60°C–65°C) whereas for R134a compressors, the top limit for condensing temperature is 158–175°F (70–80°C) for air condi- tioning applications.

What pressure should R134a run at?

22 pounds per square inch
For normal running pressures in the R134a system, at the lowest temperature, the coil should run at 22 pounds per square inch that is 45-20, 25 degrees Fahrenheit. While at the highest temperature it should be 57 pounds per square inches that is 60-20,40 degrees Fahrenheit.

What is the correct operating pressures for R134a refrigerant?

What are the Normal Operating Pressures for R134a? The pressure for an ordinarily operating R134a is between 22 and 57 pounds per square inch (PSI).

What should the pressure of R134a to recharge refrigerator?

R-134a ideally should have between 25 and 45 psi. Open the refrigerant can port, allowing refrigerant to enter the system. Close the port every minute to check the pressure. Continue to add refrigerant until the pressure has reached the correct range.

What is R123 used in?

industrial air conditioning
Used for industrial air conditioning and building climatisation for water and intermediary fluids cooling. In order to preserve the stratosferic ozone layer, R-123 is used as a replacement for R-11 (CFC) for high power air conditioning systems, fitted with centrifugal compressors (one or more stages).

Is R123 an HFC?

Introduced in the early 90s during the CFC phase-out, R123 was seen as an ideal alternative to R11 in centrifugal chiller applications. Being an HCFC, R123 is destined for phase-out around the world despite US attempts to save it from extinction based on its negligible ODP, low GWP and high efficiency.

What are good pressures for R134a?

As an air-conditioning refrigerant in newer automobiles, the optimal running pressure for R134A is between 22 and 57 pounds per square inch.

What are normal operating pressures for 1234yf?

1234yf Pressure Chart

°F °C PSI
60.8 16 111.75
64.4 18 118.55
68 20 125.63
71.6 22 132.98

What happens if you overcharged refrigerant?

A refrigerant overcharge alters the pressure inside the air conditioner and puts the compressor in danger. The Compressor: Excess refrigerant creates a danger called slugging. This is when extra refrigerant floods into the piston cylinders of the compressor when in a liquid state.

What should the pressure be on a R134A compressor?

In other words, the A/C compressor could be failing internally. What are the Normal Operating Pressures for R134a? The pressure for an ordinarily operating R134a is between 22 and 57 pounds per square inch (PSI). Remember, there are two sides to the chart; we have the low and the high.

What kind of refrigerant does a micro compressor use?

By using R134A refrigerant, RIGID micro compressor is able to run on DC or AC power through an AC-DC conversion. RIGID small dc compressor is starting a new trend in various compact mobile cooling systems as well as small footprint countertop appliances.

Which is the low side of the R134a?

Remember, there are two sides to the chart; we have the low and the high. Therefore in a normal R134a, the low-pressure side is 90 degrees or less, and the PSI should be close to 30. Why Is my Low Side AC Pressure High?

What should the working temperature of a mini compressor be?

High temperature working condition, can work under 52 degree ambient temperature. The minimum evaporating temperature and the condensing temperature allows RIGID mini compressor apply to application (LBP, MBP, or HBP). Low Back Pressure systems such as freezers have evaporator temperatures below -20ºC (-4ºF).